| Name |
Description |
Article code |
| IX71S8F-3 |
Manual inverted frame with left-side tilted sextuple nosepiece, field number 22 and light-path prism to left-side image port (80%). For transmitted and reflected illumination. Coarse and fine focussing knobs with maximum focus stroke of 9 mm and 100 µm stroke per full rotation of the fine focus knob. Minimum fine graduation 1 µm. Front control of the external light power supply. With integrated magnification changer 1.0x and 1.6x. Prepared for control of external devices via TTL pulse control switch. Cable to connect frame and external Olympus light power supply included. |
N1509400 |
| IX81S8F |
Motorised inverted frame with left-side tilted motorised sextuple nosepiece, field number 22 and motorised light-path prism to left-side image port (80%). For transmitted and reflected illumination. Motorised internal Z-drive with 0.01 µm minimum step size. Coarse and fine focussing knobs with maximum focus stroke of 9 mm. Minimum fine graduation 0.1 µm. Programmable frame keys for Z-focus escape/return, coarse/fine switching, changing of the lightpath prism and light intensity control. Indication of light intensity via front LED display. External control of microscope functions via handswitch and/or PC (RS232 communication). Cables to connect frame and IX2 controlbox included.
|
E0432000 |
Microdissection Components
| Name |
Description |
Article Code |
| Laser |
Solid state UV-A laser for cutting and isolation of target samples, 355 nm, pulse duration smaller 500psec, with repetitionrate bigger than 5KHz, maintenance free, guaranteed lifespan 5000 hrs. or minimum 1 year, 10.000 hrs. expected Fixed beam aligned in optical axis Extremely sharp focus due to computer simulated optics Computer controlled laser power Computer controlled laser focus (z-position of the beam) Safety devices and eye protection filters |
|
| Control Unit |
System control unit with complete set of wires. |
|
| Computer controlled xy-stage |
Computer controlled and motorised xy-stage 120x100 mm travelling path. 0,025 µm step width for high precision cutting. 1µm repositioning accuracy
|
|
| CapLift |
Software controlled positioning, lifting and lowering of adhesive cap, possibility to adjust contact pressure according to specific application needs. |
|
| Camera |
CellCamera DXA285cF for outstanding image quality and colour fidelity IEEE 1394a (FireWireTM progressive scan CCD camera) Ultra high sensivity Exview CCD technology and dynamic range Advanced passive cooling concept for exposure times up to 30 sec 1392 x 1040 pixels High Quality 12 Bit slow scan mode for lowest readout noise Up to 15 full frames per second Ultra compact dimensions Automatic shutter, automatic/manual white balance |
|
UV Cut Software (system control software) |
Special program for drawing the cutting path into the computer live image. Free-hand drawing or predefined figures Automatic cutting of marked areas or cells Multigroup marking and cutting of unlimited number of different groups Multiple cutting of the same area Automatic Cap Inspection Mode and automatic CapLift over full slide Store and recall of positions Documentation Scanned-in overview of slide for easy navigation Modular Software, compatible with Optical Tweezers and Cell Pick Unique PTP (Predefined Target Positioning) functions |
|
| System PC and monitor |
System computer and monitor Interactive control of motorised xy stage with real time video image on computer screen. Complete with computer Pentium IV 650, 3.4 GHz, 1 GB RAM, MS Windows XP Professional, HDD 80 GB, video overlay, 19” LCD flat screen, DVD burner, RW |
|
| CellCut Documentation |
Complete instruction manual in English as hardcopy and as .doc file on system computer |
|
| Consumables |
50 membrane slides, 50 caps with adhesive material |
|
|
|
E0439103 |
Observation Tubes, Intermediate Tubes and Eyepieces
|

|
Description |
Article code |
|
Observation Tubes |
|
| U-BI90CT-1-2 |
Binocular (Siedentopf) tube with integrated centring telescope and shutter, 45° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on right sleeve. To be used with WHN10x/22 , WHN10x-H/22 eye-pieces. |
N1510300 |
| U-TBI90 |
Binocular ergo tube with 35° to 85° tilting angle, diopter adjustment on one eyepiece, eyepoint height adjustable from 406mm to 471mm |
035774 |
|
Intermediate Tubes |
|
| U-TV0.63XC |
Camera adapter with C-mount, 0.63x magnification factor. |
N2179000 |
|
Eyepieces |
|
| WHN10X/22 |
Widefield eye-piece with fieldnumber 22. |
N1508000 |
| WHN10X-H/22 |
Focusable widefield eye-piece with fieldnumber 22. |
N1508100 |
Illumination Pillar, Lamphouse and Power Supply
|

|
Description |
Article code |
|
Illumination Pillar (100W) |
|
| IX2-ILL100 |
Tiltable illumination pillar for centerable 100 W Halogen lamp housing, 4 filter holders, F.S. and condenser support. |
35762 |
|
|
|
|
Lamphouse and Power Supply (100W) |
|
| U-LH100L-3-5 |
100 W Halogen lamphouse with collector lens and long connecting cable. |
N2212100 |
| U-RMT |
Cable for connecting the 100 W Halogen lamp house U-LH100-3-5 or IX-HLSH100 with TH-4 transformer or the BX- or IX2-UCB control-boxes for PC control of the lamp. Length 1.7 m |
37998 |
| AHS-LAMP 12V/100W |
Precentered 100 W halogen lamp |
35359 |
| TH-4 |
Transformer for 100 W Halogen lamp, 220-240 V. |
35495 |
|
Condenser
 |
Description |
Article code |
| IX2-MLWCD |
Universal ultra long working distance condenser for brightfield, Olympus relief contrast, phase contrast and DIC. With numerical aperture of 0.5, working distance of 45 mm. Equipped with aperture stop and polariser for relief contrast. Four-position turret includes the relief contrast elements RC1, RC2 and RC3. |
35771 |
Range of Objectives
|

|
Description |
Article Code |
|
Note: Only the following objectives are offered for cutting. The full range of objectives can be found under Objectives & Accessories. For the optimal choice of objectives according to your application please Contact Us. |
| UPLFLN4x/0,13 |
Universal Plan Fluorite objective with 4x magnification. With working distance of 17 mm, and numerical aperture of 0.13. Suitable for any cover slip thickness. |
N1478300 |
| UPLFLN10x/0,3 |
Universal Plan Fluorite objective with 10x magnification. With working distance of 10 mm und numerical aperture of 0.3. Suitable for any cover slip thickness. |
N1478400 |
| UPLFLN10XPH/0,3 |
Universal Plan Fluorite objective with 10x magnification. With working distance of 10 mm and numerical aperture of 0.3. Suitable for any cover slip thickness. For phase contrast observations (PH1). |
N1479200 |
| LUCPLFLN20X/0.45 |
Long working distance Universal CPlan Fluorite objective with 20x magnification. With variable working distance from 6.6 to 7.8 mm, numerical aperture of 0.45 and variable cover correction from 0 to 2 mm via correction collar. |
N1492700 |
| LUCPLFLN20XPH/0.45 |
Long working distance Universal Cplan Fluorite objective with 20x magnification. With variable working distance from 6.6 to 7.8 mm, numerical aperture of 0.45 and variable cover correction from 0 to 2 mm via correction collar. For phase-contrast observations (PH1). |
N1492900 |
| LUCPLFLN40X/0,6 |
Long working distance Universal CPlan Fluorite objective with 40x magnification. With variable working distance from 2.7 to 4 mm, numerical aperture of 0.6 and variable cover correction from 0 to 2 mm via focus free correction collar. |
N1492800 |
| LUCPLFLN40XPH/0.6 |
Long working distance Universal Cplan Fluorite objective with 40x magnification. With variable working distance from 3 to 4.2 mm, numerical aperture of 0.6 and variable cover correction from 0 to 2 mm via focus free correction collar. For phase-contrast observations (PH2). |
N1493000 |
| LUCPLFLN60X/0,7 |
Long working distance Universal CPlan Fluorite objective with 60x magnification. With variable working distance from 1.5 to 2.2 mm, numerical aperture of 0.7 and variable cover correction from 0.1 to 1.3 mm via semi focus free correction collar. |
N1507100 |
| LUCPLFLN60XPH/0.7 |
Long working distance Universal CPlan Fluorite objective with 60x magnification. With variable working distance from 1.5 to 2.2 mm, numerical aperture of 0.7 and variable cover correction from 0.1 to 1.3 mm via semi focus free correction collar. For phase-contrast observations (PH2). |
N1507200 |
| UPLFLN100xO2/1.3 |
Universal Plan Fluorite oil immersion objective with 100x magnification. With working distance of 0.2 mm, numerical aperture of 1.3 and cover correction of 0.17 mm. |
N1561200 |
| UPLFLN100xO2PH/1.3 |
Universal Plan Fluorite oil immersion objective with 100x magnification. With working distance of 0.2 mm, numerical aperture of 1.3 and cover correction of 0.17 mm. For phase-contrast observations (PH3). |
N1561400 |
Fluorescence Equipment (optional)
 |
Description |
Article Code |
|
Fluorescence Adaption |
| MMI-FLUO-AD |
Integration of Olympus fluorescence items plus SW functions |
E0439239 |
|
Lamphouse, Power Supply and Burner |
| U-LH100HG |
Lamphouse incl. lamp socket and aspherical collector lens for 100W mercury lamp. |
037940 |
| U-RFL-T2-200 |
Power supply for 100W mercury lamp, 220-240 V/50-60Hz, 3 fuses for replacement. |
037947 |
| USH-103OL |
USHIO 100W mercury burner |
N1217800 |
| UYCP |
Power cord |
037940 |
|
Fluorescence Condenser |
|
| IX2-RFAL |
L-shaped fluorescence condenser, with centerable aperture stop, field stop and filter slider |
35764 |
|
Fluorescence Cubes |
|
| U-MNU2 |
Fluorescence filter cube, narrow-band UV excitation: exciter filter BP360-370, beam splitter DM400, barrier filter BA420 |
37056 |
| U-MWIBA3 |
Fluorescence filter cube with Ion-coated filters. Wide-band Blueexcitation with bandpass emitter: exciter filter BP460-495, dichroic beam splitter DM505, barrier BA510-550 |
N1511000 |
| U-MWG2 |
Fluorescence filter cube, wide-band Green excitation: exciter filter BP510-550, dichroic beam splitter DM570, barrier filter BA590 |
37063 |
| IX2-RFAC |
Fluorescence cube cassette, six-position turret and manual shutter. |
35765 |
|
Motorisation (with IX81)
| Name |
Description |
Article Code |
| IX2-UCB-2 |
Control box for the motorised units, equipped with power source for U-LH100L-3, including IX2-BSW basis software |
N1169600 |
| U-ZPCB |
Z-drive control board for the UCB control units, necessary for operating the motorised focusing unit for the motorised frames of the BX2 and IX2 series |
37996 |
| UYCP |
Power Cord |
35425 |
| BX-UCBRS232 |
Special RS232 cable (with socket/socket) for connecting the control box with the PC. |
39638 |
|
|
|
|
Motorised Fluorescence Components |
|
| IX2-RFAL |
L-shaped fluorescence condenser, with centerable aperture stop, field stop and filter slider |
35764 |
| IX2-RFACA |
Motorised six-position fluorescence cube cassette with manual shutter |
35766 |
| IX2-SHA |
Motorised shutter for reflected and transmitted light |
35801 |
|
|
|