Specifications for DSU |
 |
Resolution enhancement by removal of out of focus blur
Sharp, high contrast semi-confocal images
Cost efficient optical sectioning
Reduced post image processing efforts
|
Back to main page |
Print |
DSU Sets
| Name |
Description |
Article Code |
| _IX2-DSU |
Disk scanning unit for IX2: DU-DBX DSU body; motorised fluorescence turret (IX2-RFACA, mounted inside DSU body); U-FWR filter wheel for ND filters, loaded with: free, ND25, ND12, ND6, ND3, ND1.5; DU-MTDRV motor drive board to be mounted in IX2-UCB; Disk2 included as standard; DU-HSW hand switch, cable; DU-STIX supporter for illumination unit; DU-RFAIX: illuminator to couple microscope frame and DSU body; IX2-RFAC special: non-motorised filter turret loaded with 100% mirror in pos. 1 to be mounted in the microscope; RFP and GFP fluorescence filterset |
E0435082 |
| _IX2-DSU/MT |
IX2 Disk scanning unit for cell^M/cell^R imaging stations modified for MT10/MT20 illumination systems: DU-DBX DSU body; motorised fluorescence turret (IX2-RFACA, mounted inside DSU body); MT_CON/DSU illuminator to couple MT10/20 to DSU body; DU-MTDRV motor drive board to be mounted in IX2-UCB; Disk2 included as standard; DU-HSW hand switch, cable; DU-RFAIX: illuminator to couple microscope frame and DSU body; IX2-RFAC special: non-motorised filter turret loaded with 100% mirror in pos. 1 to be mounted in the microscope; RFP and GFP fluorescence filterset |
E0435083 |
| _BX-DSU |
Disk scanning unit for BX2: DU-DBX DSU body; motorised fluorescence turret (IX2-RFACA, mounted inside DSU body); U-FWR filter wheel for ND filters, loaded with: free, ND25, ND12, ND6, ND3, ND1.5; DU-MTDRV motor drive board to be mounted in IX2-UCB; Disk2 included as standard; DU-HSW hand switch, cable; DU-STIX supporter for illumination unit; DU-RFABX: special light illuminator with non-motorised filter turret loaded with 100% mirror in pos. 1; RFP and GFP fluorescence filterset; DSU-CAD: C-mount adaptor for DSU body; BX only: arm-lift kit WI-ARMAD to lift DU-RFABX and adapter DSU-READ to adjust revolving nosepiece position only for BX51 |
E0435080 |
| _BX-DSU/MT |
BX2 Disk scanning unit for cell^M/cell^R imaging stations modified for MT10/MT20illumination systems: DU-DBX DSU body; motorised fluorescence turret (IX2-RFACA, mounted inside DSU body); MT_CON/DSU illuminator to couple MT10/20 to DSU body; DU-MTDRV motor drive board to be mounted in IX2-UCB; Disk2 included as standard; DU-HSW hand switch, cable; DU-RFABX: special light illuminator with non-motorised filter turret loaded with 100% mirror in pos. 1; RFP and GFP fluorescence filterset; DSU-CAD: C-mount adaptor for DSU body; BX only: arm-lift kit WI-ARMAD to lift DU-RFABX and adapter DSU-READ to adjust revolving nosepiece position only for BX51 |
E0435081 |
Compatible Frames
| Name |
Description |
Article Code |
| BX61TRF |
Motorised microscope frame with built-in motorised high accuracy focusing unit (accuracy 0.01µm, repeatability 1µm) and 8 programmable frame keys for the control of motorised functions, built-in LBD-IF/ND6/ND25 filters. |
37006 |
| BX61WIF |
BX61WIF microscope frame with fixed stage, Motorised focusable nosepieceholder, incl. internal high accuracy z-drive motor with 0.01µm step increment, incl. 4 position 32mm filter wheel, eight programmable frame keys. |
38747 |
| IX81S1F |
Frame with left-side tilted sextuple nosepiece, high reflection optical path (FN22), integr. magnification changer 1.0x and 1.6x, optical light-path prism to left-side image port (100%) |
E0432001 |
| IX81S8F |
Frame with left-side tilted sextuple nosepiece, high reflection optical path (FN22), integr. magnification changer 1.0x and 1.6x, optical light-path prism to left-side image port (80%) |
E0432000 |
| IX81B1F |
Frame with left-side tilted sextuple nosepiece, high reflection optical path (FN22), integr. magnification changer 1.0x and 1.6x, optical light-path prism to left-side image port (100%) and manual bottom port |
E0432003 |
| IX81S1BAF |
Frame with left-side tilted sextuple nosepiece, high reflection optical path (FN22), integr. magnification changer 1.0x and 1.6x, optical light-path prism to back-side image port (80%) and bottom port |
E0432005 |
Light Sources and Illumination Systems
| Name |
Description |
Article Code |
| U-LH100HG |
Lamphouse incl. lamp socket and aspherical collector lens for 100W mercury lamp |
37940 |
| U-LH100HGAPO |
Lamphouse incl. lamp socket and aspherical, apochromatic corrected collector lens for 100W mercury burner |
37941 |
| MT10 |
Short arc burners, 150 W Xenon or Mercury-Xenon (recommended); 8 Filter positions (diameter 25 mm); Filter switch (min. 85 ms from neighbouring positions); Attenuation: 7 levels, 4% - 100%; Attenuation switch: <85 ms; Shutter, on/off time: 5 ms; Operation: sequentially |
|
| MT20 |
Short arc burners, 150 W Xenon or Mercury-Xenon (recommended); 8 Filter positions (diameter 25 mm); Filter switch (min. 58 ms from neighbouring positions); Attenuation: 14 levels, 1% - 100%; Attenuation switch: <58 ms; Shutter, on/off time: 1 ms; Operation: all modules in parallel |
Spinning Slit Disks
| Name |
Description |
Article Code |
| _DSU-D1 |
DISK-1 for DSU: for objectives UPLAPO20xO, UPLFLN40xO recommended for thick specimen |
E0435085 |
| _DSU-D2 |
DISK-2 for DSU: for thin specimen |
E0435086 |
| _DSU-D3 |
DISK-3 for DSU: for objectives UPLAPO20xO, UPLSAPO40x, PLAPON60xO, UPLFLN40xO |
E0435087 |
| _DSU-D4 |
DISK-4 for DSU: for objectives LUMPLFL60xW, UPLAPO100xOI, PLFL100xOI |
E0435088 |
| _DSU-D5 |
DISK-5 for DSU: for objective XLUMPLFL20xW |
E0435089 |
Cameras
Several high-end CCD und EMCCD cameras of reputable manufacturers are supported. Contact Your Local Sales Representative for detailed expert advice.
Software
|
|
|