Specifications for CKX31

Advanced optical system
Multifunctional stages
Easy operation and transport
Leading in its class of microscopes
Back to main page Print
Key FeaturesSpecificationsDimensionsApplications

Frame
Stage Accessories
Contrast Slider
Objectives
Filter


Frame

Name  Description Article Code
CKX31SF-5 Microscope frame for UIS2 optics with fixed binocular tube FN20, incl. 2 eyepieces WHB10x, integrated quadruple revolving nosepiece, plain stage (160x250mm), coarse and fine focusing with tension adjustment mechanism, illuminator pillar with lamphouse and long working distance condenser NA 0.3, WD=72mm, aperture stop, allen key AQ2302, transformer integrated in frame, incl. lamp socket and two halogen bulbs (30W) N2187000
     
  Halogen Bulb  
6V30W 6V30W halogen bulb E0430150
Top
Stage Accessories

Name  Description Article Code
CK40-MVR Attachable specimen guide, right-hand low driven coaxial stage control, movement range: x=120mm, y=78mm, with 3 inserts: 1) for slides and Petri dishes 54mm ø, 2) for microtiter plates (60 or 72) & Petri dishes 65mm ø, 3) plate 80x55mm for Petri dishes 30mm ø 031538
CK2-SS Stage extension plate for CK40/30, CK-2, IX 030362
Top
Contrast Slider

Name  Description Article Code
  Phase Contrast (Precentered, Common Phase Ring 10x - 40x), needs PHP Objectives  
IX2-SLP "Centering free" phase contrast slider with 3 positions,  equipped with IX2-PHL and common phase annular stop (10x, 20x and 40x) and BF postion, to use with PHP objectives N1140300
     
  Phase Contrast (Centerable), needs PH Objectives  
IX2-SL Centerable phase contrast slider with 3 positions,  equipped with IX2-PHL phase annular stop, two empty positions 035793
IX2-SLPHC PHC Phase annular stop for center slider position and for CPL10xPH, CPLFL10xPH, LCACH20xPH, for IX2-SL condenser slider 035794
IX2-SLPH1 PH1 Phase annular stop for center position of IX2-SL condenser N1140100
IX2-SLPH2 PH2 Phase annular stop for right position of IX2-SL condenser 035795
CT-5 Centering telescope for phase contrast, diameter 23.5mm 031194
  Note: Alternative use of IX2-SLPHC or IX2-SLPH1 corresponding to used objectives.  
     
  Relief Contrast  
CKX-RCD RC condenser NA 0.45, WD 45mm for CKX41 and CKX31, including two position slider for RC modulators (10x and common for 20x/40x); if one position is not used by modulator BF can be performed N1157782
CT-5 Centering telescope for phase contrast, diameter 23.5mm 031194
Top
Objectives

Name  Description Article Code
  Brightfield Plan Achromat Objectives  
PLCN4x/0.1 C Plan Achromat 4x with 18.5 mm working distance and numerical aperture (NA) of 0.1 . N1216600
PLCN10x/0.25 C Plan Achromat 10x with 10.5 mm working distance and numerical aperture (NA) of 0.25.  N1216700
PLCN20x/0.40 C Plan Achromat 20x with 1.2 mm working distance and numerical aperture (NA) of 0.40. Cover correction = 0.17 . N1216800
PLN2x/0.06 Plan Achromat 2x with 5.8 mm working distance and numerical aperture (NA) of 0.06.  N1215600
 

 

PHP Phase Contrast Objectives

 
UPLFLN4xPHP/0.13 U Plan Fluorite Phase 4x with 16.4 mm working distance, numerical aperture (NA) 0.13 . For IX2-PHL ring in IX2-SLP N1507400
CACHN10xPHP Achromat Phase 10x with 8.8 mm working distance, numerical aperture (NA) 0.25 . For common phase ring in IX2-SLP N1507300
LCACHN20xPHP/0.40 Long working distance Achromat Phase 20x with 3.2 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1. For common phase ring in IX2-SLP. N1477800
LCACHN40xPHP/0.55 Long working distance Achromat Phase 40x with 2.2 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1.  For common phase ring in IX2-SLP. N1477900
     
  PH Phase Contrast Objectives  
UPLFLN4xPH/0.13 U Plan Fluorite Phase 4x with 17 mm working distance, numerical aperture (NA) 0,13 . For IX2-PHL phase annular stop. N1479100
CPLN10xPH/0.25 Plan Achromat Phase 10x with 10 mm working distance and numerical aperture (NA) of 0.25. To be used with PHC phase annular stop. N1507800
LCACHN20xPH/0.4 Long working distance Achromat Phase 20x with 3.2 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1mm. To be used with PHC phase annular stop. N1477600
LCACHN40x2PH/0.55 Long working distance Achromat Phase 40x with 2.2 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1mm. To be used with PH2 phase annular stop. N1477700
     
  Relief Contrast Objectives  
CPLN10xRC/0.25 Plan Achromat Relief Contrast 10x with 9.7 mm workingdistance, numerical aperture (NA) 0.25 .  N1507900
LCACHN20xRC/0.40 Long working distance Achromat Relief Contrast 20x with 2.8 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1.5 mm. N1478000
LCACHN40xRC/0.55 Long working distance Achromat Relief Contrast 40x with 1.9 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1.5 mm.  N1478100
     
  This selection focuses on the objectives most used with CKX31. The full range of objectives can be found under Objectives & Accessories.  
Top
Filter

Name  Description Article Code
45LBD-2 Colour temperature compensation filter, 45mm ø 035126
43ND-25W45 Neutral density filter 035137
43IF-550-W45 Interference filter 035159
45KB-4-L Daylight filter 45mm ø 035167