CLV-290SL

EVIS LUCERA ELITE Xenon Light Source

With the EVIS LUCERA ELITE Xenon Light Source CLV-290SL, pre-procedure setup has never been easier thanks new One-touch Connector for EVIS LUCERA ELITE endoscopes.

Key benefits

Brighter, more powerful Narrow Band Imaging

Narrow Band Imaging now delivers significantly increased brightness and contrast. Previously widely accepted as a characterisation tool, the improved brightness may open new possibilities for lesion detection.

Improved Auto Fluorescence Imaging

An increased frame rate results in decreased noise in images and ultimately a higher resolution of Auto Fluorescence Imaging when compared with EVIS LUCERA SPECTRUM, this enables more accurate observation of mucosal conditions.

Improved ergonomics

The all-new One-touch Connector of EVIS LUCERA ELITE endoscopes allows for one-step connection to the light source and removes the need for a video cable connection to the video processor.

Power SupplyVoltage100–240 V AC; within ±10%
 Frequency50/60 Hz; within ±1 Hz
 Consumption electric power600 VA
SizeDimensions (W x H x D)370 x 150 x 476 mm (standard)
390 x 162 x 551 mm (maximum)
 Weight18 kg
IlluminationExamination lampXenon short-arc lamp (ozone-free) 300 W
 Average lamp lifeApproximately 500 hours of continuous use (With intermittent use, the lamp life may vary slightly.)
 Ignition methodSwitching regulator
 Brightness adjustmentLight-path diaphragm control
 CoolingForced-air cooling
 NBI observationAvailable
 AFI observationAvailable
 IRI observationAvailable
 Emergency lampHalogen lamp (within mirror) 12 V 35 W
 Average emergency lamp lifeApproximately 500 hours
Automatic Brightness
Adjustment
Automatic brightness adjustment methodServo-diaphragm method
 Automatic exposure17 steps
Air FeedingPumpDiaphragm type pump
 Pressure switching4-level available (OFF, low, medium, high)
Water FeedingMethodFeeds water by pressurizing the detachable water container with air.
Indicators on Front
Panel
Emergency lampIndicates absence of emergency lamp, disconnection and use of emergency lamp.
 NBIWhen the NBI observation is enabled, the NBI indicator lights up.
 AFIWhen the AFI observation is enabled, the AFI indicator lights up.
 IRIWhen the IRI observation is enabled, the IRI indicator lights up.
Setting Memory Settings (except filter setting) are stored even when the light source is OFF.
Classification (medical electrical equipment)Type of protection against electric shockClass I
 
Degree of protection against electric
shock of applied part
TYPE BF applied part
NOTE: The applied part as classification types are not marked is the TYPE BF applied part.
 Degree of protection against explosionThis instrument should be kept away from flammable gases.

Contact and Support

What Can We Help You With?

Contact Us

Whether you’re looking for answers, would like to solve a problem, or just need to get in touch, you can contact us right here.

To Contact Form

Event Calendar

Find out more about our certified international medical expert training courses in over 25 reference centers across 13 countries in Europe.

To our Trainings and Events

Media Center

Discover our Media Center for further information about our products and services, such as brochures, documents, images, and videos.

To our Media Center


IMAGINE...

IMAGINE...

an Endoscope Would Have an Analgesic Effect

More
EndoAtlas
Training tool

EndoAtlas

Clinical data and endoscopic training tools from renowned physicians.

More